Q: MFR and MVR are tested by the same standards, ASTM D1238 and ISO 1133, are they considered the same property in the Prospector Property Search? If you search on one will it automatically return results for both?
A: No. MFR (g/10min) and MVR (cm³/10min) are reported with different units, therefore not relateable in the Property Search. If you searched on MFR you would then need to also search on MVR to see the 2,888 materials that have both properties listed.
You may search on both ASTM and ISO standards simultaneously with the combined standards folder. For example you can search MFR and your results will include materials tested by ASTM D1238 and ISO 1133.
-Melissa
800-788-4668 x214